Bộ Datalogger công suất 3 pha Fluke 1735

Xuất xứ: Đức

Bảo hành: 12 Tháng

Liên hệ

Hướng dẫn khi mua hàng

  • Quý khách có thể "Thanh toán khi nhận hàng"
  • Quý khách có thể "Thanh toán qua tài khoản"

Hãng sản xuất: FLUKE

Model: 1735

Xuất xứ: Đức

Bảo hành: 12 tháng

Thông số kỹ thuật:

 

Display: ¼ VGA Graphic Color transmissive displays 320 x 240 Pixel with additional background lighting and adjustable contrast, text and graphics in color
Quality: Developed, designed and manufactured according to DIN ISO 9001
Memory: 4 MB Flash memory, 3.5 MB for measuring data
Interface: RS-232 SUB-D socket; 115.2 k Baud, 8 data bits, no parity, 1 stop bit, firmware updates are possible with the RS- 232 interface (9-pole extension cable)
Sample rate: 10.24 kHz
Line frequency: 50 Hz or 60 Hz, user-selectable, with automatic synchronization
Power supply: NiMH battery-pack, with ac adapter (15 V to 20 V/0.8 A)
Operation time with battery: Typical > 12 hours without backlight and > 6 hours with backlight high
Dimensions: 240 mm x 180 mm x 110 mm
Weight: 1.7 kg, including battery
Ambient conditions
Working temperature range: -10 °C to +50 °C
Storage temperature range: -20 °C to +60 °C
Operating temperature range: 0 °C to +40 °C
Reference temperature range: 23 °C ± 2 °C
Note: The above terms are defined in European Standards. To calculate the specification at any point in the working temperature range, use the temperature coefficient below.
Temperature coefficient: ± 0.1 % of the measured value per °C from the reference
Intrinsic error: Refers to reference temperature, maximum deviation is guaranteed for two years
Operating error: Refers to operating temperature range, maximum deviation is guaranteed for two years
Climatic class: C1 (IEC 654-1) -5 °C to +45 °C, 5% to 95% RH, no dew
Housing: Cycoloy shock and scratch proof thermoplast V0-type (non-flammable) with rubber protection holster
EMC
Emission: IEC/EN 61326-1:1997 class B
Immunity: IEC/EN 61326-1:1997
Safety Specifications:
Safety: IEC 61010-1 600 V CAT III, double or reinforced insulation, pollution degree 2
Protection: P65; EN60529 (refers only to the main housing without the battery compartment)
RMS values are measured with a 20 ms resolution.
V-rms wye measurement:
Measuring range: 57 V/66 V/110 V/120 V/127 V/220 V/230 V/240 V/260 V/277 V/347 V/380 V/400 V/417 V/480 V ac
Intrinsic error: ± (0.2% of measured value + 5 digits)
Operating error: ± (0.5% of m. v. + 10 digit)
Resolution: 0.1 V
V-rms delta measurement
Measuring range: 100 V/115 V/190 V/208 V/220 V/380 V/400 V/415 V/450 V/480 V/600 V/660 V/690 V/720 V/830 V ac
Intrinsic error: ± (0.2% of m. v. + 5 digit)
Operating error: ± (0.5 % of m. v. + 10 digit)
Resolution: 0.1 V
A-rms measurement
Flexi set I ranges: 15 A/150 A/3000 A rms (at sine)
Current clamp ranges: 1 A/10 A
Resolution: 0.01 A
Ranges 150 A/3000 A and 1 A/10 A
Operating error: ± (1 % of m. v. + 10 digit)
Ranges 15 A
Intrinsic error: ± (0.5 % of m. v. + 20 digit)
Operating error: ± (1 % of m. v. + 20 digit)
The errors of the current probes are not considered.
By using Flexi-Set
Flexi Set measuring error: ± (2% of m. v. + 10 digit)
Position influence: ± (3 % of m. v. + 10 digit)
CF (typical): 2.83
Note: When using Flexi Set please make sure to position the conductor opposite to the Flexi Set-lock
Power measurement (P – Active, S – Apparent, Q- reactive, D – Distorting
Measuring range: see V rms and A rms measurement
Power errors are calculated by adding the errors of voltage and current
Additional error due to power factor PF
Specified error x (1-[PF])
Maximum range with voltage range 830 V delta-connection and 3000 A current range is 2.490 MW, higher displayed values possible when using PTs and CTs with ratio feature
Intrinsic error: ± (0.7 % of m.v. +15 digit)
Resolution: 1 kW
Operating error: ± (1.5 % of m.v. + 20 digit)
Typical range with voltage range 230 V wye connection and 150 A current range is 34.50 KW.
Intrinsic error: ± (0.7 % of m.v. +15 digit)
Resolution: 1 W to 10 W
Operating error: ± (1.5 % of m.v. + 20 digit)
The errors of the current sensors themselves have not been considered.
Energy measurement (kWh, KVAh, kVARh)
Intrinsic error: ± (0.7 % of m.v.+ F variation error* + 15 digit)
Resolution: 1 W to 10 W
Operating error: ± (1.5 % of m.v. + F variation error* + 20 digit)
*Frequency variation error
PF (Power factor)
Range: 0.000 to 1.000
Resolution: 0.001
Accuracy: ±1 % of full scale
Frequency measurement
Measuring range: 46 Hz to 54 Hz and 56 Hz to 64 Hz
Intrinsic error: ± (0.2 % of m. v. + 5 digit)
Operating error: ± (0.5 % of m. v.+ 10 digit)
Resolution: 0.01 Hz
Harmonics
Measuring range: To 50th harmonic (< 50 % of nom)
Accuracy
Vm, Im, THDV, THDI: IEC 61000-4-7:2002, Class II
Vm ≥ 3% Vn: ± 5% Vm
Vm < 3 % Vnom: ±0.15% Vnom
Im ≥ 10 % Inom: ± 5% Im
Im < 10 % Inom: ± 0 5% Inom
THDV: for THD < 3% ± 0.15% at Vnom
for THD ≥ 3% ± 5% at Vnom
THDI: for THD < 10% ± 0.5% at Inom
for THD ≥ 10% ± 5% at Inom
Vnom: Normal voltage range
Inom: Nominal current range
Vm and Im are measured values of harmonic m
Events
  Detection of voltage dips, voltage swells and voltage interruptions with a 10 ms resolution and measuring error of the half period sine wave of rms.
Intrinsic error: ± (1% of m.v. + 10 digit)
Operating error: ± (2% of m.v. + 10 digit)
Resolution: 0.1 V

 

 

 Bộ Datalogger công suất 3 pha Fluke 1735: Thiết lập nhanh chỉ trong vài phút tự động giám định và phân tích chất lượng điện năng. Dự đoán Load – xác suất hệ thống điện trước khi thêm tải. Đánh giá năng lượng – đinh lượng tiêu thụ năng lượng trước và sau khi cải tiến. Phát hiện ra vấn đề hài hoà mà có thể gây thiệt hại hoặc phá vỡ thiết bị quan trọng. Ghi điện và các thông số liên quan đến 45 ngày.

Sản phẩm tương tự

  • Liên hệ
    435-ll

    Xuất xứ: Romania

    Máy phân tích chất lượng điện và năng lượng điện ba pha FLUKE 435-ll: Nhanh chóng xem có bao nhiêu năng lượng đang bị lãng phí, về mặt đô la thực. Dễ dàng xem cách khởi động động cơ ảnh hưởng đến hiệu suất ổ đĩa động cơ. Nhận dữ liệu sức khỏe chất lượng cao trong nháy mắt trong thời gian thực để đưa ra quyết định bảo trì tốt hơn. Nắm bắt mọi phép đo tự động mà không cần bất kỳ thiết lập nào. Đo tất cả ba pha và trung tính với đầu dò hiện tại linh hoạt bao gồm. Xếp hạng an toàn: 600V CAT IV / 1000V CAT III được xếp hạng để sử dụng tại lối vào dịch vụ. Fluke Connect tương thích  
  • Liên hệ
    345

    Xuất xứ: FLUKE

    Ampe kìm phân tích công suất AC / DC Fluke 345: Thiết lập và khắc phục sự cố các ổ đĩa biến tần và các hệ thống UPS – Xác minh hoạt động chính xác bằng cách đo các thông số chất lượng nguồn chính. Phép đo hài hoà – khám phá các vấn đề hài hoà có thể làm lỏng hoặc làm gián đoạn thiết bị quan trọng. Inrush capture – kiểm tra khởi động hiện tại, nơi xảy ra reset giả hoặc ngắn mạch gây phiền toái. Tải nghiên cứu – xác minh dung lượng hệ thống điện trước khi thêm tải
  • Liên hệ
    GPM-8213

    Xuất xứ: Gwinstek - Đài Loan

    Model: GPM-8213. Hãng sản xuất: Gwinstek Xuất xứ: Đài Loan Bảo hành: 12 tháng. Chế độ: 1P2W / AC, DC Thông số đo: Vdc/ Vrms/ V+pk/ V-pk, Idc/ Irms/ I+pk/ ...
  • Liên hệ
    1744

    Xuất xứ: USA

    Bộ Datalogger công suất 3 pha Fluke 1744: Là công tơ điện hàng ngày cho các kỹ thuật viên khắc phục sự cố và phân tích các vấn đề về chất lượng điện. Có khả năng ghi đồng thời lên đến 500 thông số công suất lên đến 85 ngày và theo dõi các sự kiện, các logger điện này giúp phát hiện các vấn đề về chất lượng điện liên tục và khó tìm. Phần mềm PQ Log đi kèm nhanh chóng đánh giá chất lượng điện tại lối vào dịch vụ, trạm biến áp hoặc tại tải, theo tiêu chuẩn EN50160 mới nhất.
  • Liên hệ
    434-ll

    Xuất xứ: Romania

    Máy phân tích chất lượng điện ba pha Fluke 434-ll: Nhanh chóng xem có bao nhiêu năng lượng đang bị lãng phí, về mặt đô la thực. Nhận dữ liệu sức khỏe chất lượng cao trong nháy mắt trong thời gian thực để đưa ra quyết định bảo trì tốt hơn. Xếp hạng an toàn: 600V CAT IV / 1000V CAT III được xếp hạng để sử dụng tại lối vào dịch vụ. Fluke Connect tương thích